I 1716 I
the eyepiece using the direction keys on the hand control-
ler and press the ALIGN button. This will accept the star
as the first alignment position. (There is no need to adjust
the slewing rate of the motors after each alignment step.
The NexStar automatically selects the best slewing rate for
aligning objects in both the finderscope and the eyepiece).
7. For the second alignment object, choose a bright star or
planet as far as possible from the first alignment object.
Once again, use the direction keys to center the object in
the finderscope and press ENTER. Center the object in
the eyepiece, then press the ALIGN button.
8. Repeat the process for the third alignment star. When the
telescope has been aligned to the final stars, the display
will read “Align Success.
Aligning with Auto Two Star
After the first star is selected and centered, the second star
will automatically be chosen for the best possible alignment.
Once selected, the telescope will automatically slew to the
second alignment star to complete the alignment.
1. Flip the NexStar’s power switch on. The hand control will
display “Verifying Packages…” After a few seconds it will
display “Evolution.” Scroll down using the “9” Scroll key
and press ENTER to choose Auto Two Star.
2. Press ENTER and you will be prompted to enter the local
time in 24-hour format. Ex. 21:00 for 9PM.
3. Select Daylight Savings or Standard Time, toggle the 6 &
9 (up and down scrolling keys) to change.
4. Select time zone, then enter the date. Press ENTER each
time to proceed to the next prompt.
5. The display will now prompt you to “Select Star 1” from
the displayed list on the hand control. Use Up and Down
scroll keys (6 and 9 on the keypad) to scroll to the desired
star and then press ENTER.
6. Use the direction keys to slew the telescope to the star
you selected. Center the star in the StarPointer and press
ENTER. Finally, center the star in the eyepiece and press
ALIGN.
7. The hand control will automatically display the most
suitable second alignment star that is above the horizon.
Press ENTER to automatically slew the telescope to the
displayed star. If for some reason you do not wish to select
this star (perhaps it is behind a tree or building), you can
either:
Press the UNDO button to display the next most suitable
star for alignment.
Use the UP and DOWN scroll keys to manually select any
star you wish from the entire list of available stars.
8. Repeat the same process of centering the star in your
StarPointer, press ENTER, then center in your eyepiece
and press ALIGN.
When the telescope has been aligned to both stars the
display will read Alignment Success. You are now ready to
find your first object.
Using a Wedge with EQ North /
EQ South Alignment
EQ North and EQ South Alignments assist the user in
aligning the telescope when polar aligned on an optional
equatorial wedge.
EQ AutoAlign
1. Select EQ North (for northern hemisphere) or South (for
southern hemisphere) Align from the alignment options
and press ENTER.
2. Enter time, date, and location information as with all other
alignments.
3. Select EQ AutoAlign method and press ENTER
4. Use the direction arrow keys to move the telescope until
the altitude and meridian index markers are aligned. The
altitude index marker is located at the top of the fork arm,
and the meridian marker is on the base of the fork arm.
The tube should be perpendicular to the fork arm and
facing the meridian.
5. The display will now prompt you to “Select Star 1” from
the displayed list on the hand control. Use Up and Down
scroll keys (6 and 9 on the keypad) to scroll to the de-
sired star and then press ENTER.
6. Use the direction keys to slew the telescope to the star
you selected. Center the star in the StarPointer and press
ENTER. Finally, center the star in the eyepiece and press
ALIGN.
7. The hand control will automatically display the most
suitable second alignment star that is above the horizon.
Press ENTER to automatically slew the telescope to the
displayed star. If for some reason you do not wish to select
this star (perhaps it is behind a tree or building), you can
either:
Press the UNDO button to display the next most suitable
star for alignment.
Use the UP and DOWN scroll keys to manually select any
star you wish from the entire list of available stars.
8. Repeat the same process of centering the star in your
StarPointer, press ENTER, then center in your eyepiece
and press ALIGN.
When the telescope has been aligned to both stars the
display will read Alignment Success. You are now ready to
find your first object. Tracking will now occur equatorially,
moving in just one direction to keep the object centered in
the telescope’s field of view without rotating. This tracking is
suitable for astroimaging.
NexStar Evolution Telescope
Settings in NexStar+ Hand Control
Press Menu, scroll to the “Peripherals” menu and press
ENTER. Here, you can control L.E.D. brightness of the logo
lights and accessory tray lighting, check the battery status, or
set more advanced features including external power supply
and USB charge port settings.
Adjust the L.E.D. Brightness
1. Scroll to “Mount Lights” and press ENTER.
2. Scroll to select Tray Light, WiFi Light, or Logo Light and
press ENTER.
3. Select a brightness value from 0-10, 0 being OFF, and
10 being fully lit. Press ENTER and the new brightness
setting will take effect.
Power
1. Scroll to “Power” and press ENTER.
2. Scroll to select “Status” or “External Power” and press
ENTER
Status will display the battery voltage, if the battery
charge state is High, Medium, or Low, and if the battery
is charging or discharging.
External Power allows you to select a higher input current
if you are using a higher capacity power supply. Values
can be between 2 and 5 amperes as specified on your
power supply. Do not change this setting unless you
are using a larger capacity supply. The included power
supply should always be set to 2.0A.
WiFi
1. Scroll to “WiFi” and press ENTER.
2. Scroll to select “Status” or “Enable/Disable” and press
ENTER
Status will display the WiFi mode, Direct Connect or
Access Point, and whether or not the WiFi is connected
to a network
Enable/Disable will optionally allow you to disable the
WiFi broadcast. The WiFi L.E.D. will shut off indicating it
has been disabled. Every time you power off and on the
mount again, this setting defaults to Enabled.
USB Charge Port
1. Scroll to “Charge Port” and press ENTER.
2. Press ENTER to toggle between “Automatic” or “Always
On”. “Always On” keeps the charge port going, even in a
low battery condition. “Automatic” automatically disables
the USB Charge Port when battery power is low.